Combined Boiler

|
The particularity of boiler is of being constituted by two independent combustion chambers, which, but, goes to act in an only boiler body. Boilers model CL COMBI, are manufactured according to the EN 303-1 and EN 303-5 Europeans Normatives.
The first combustion chamber is realized for wood function, with natural aspiration.
It’s equipped with a thermostat for mechanical regulation of boiler temperature that, acting on the porthole of entrance of combustive air, permits the flux air regulation.
The thermostat with the increase of water temperature in the boiler,permits to close the porthole of entrance of combustive air, determining the decrease of air flx so to decrease the flame, when it has the decrease of temperature in the boiler happens the contrary, it means that the thermosta of regulation permits the opening of porthole of intrance combustive air to increase the flame.
The second combustion chamber is realized in steel, with 5smokes turns, for the function of a gasoil burner. The system of function of burner can be regulated with a digital electronic board, that control the differents phases of functioning. On the electronic board can be controlled, checked the main functions of burner and of boiler, like:
- The circulation pump of system
- The regulator thermostat of boiler
Download the documentation
|